Blowers & Parts
-
Vendor: SERVICE FIRST
CTV Flanged Bearing 1.62" Bore 4 1/2" Wide
SCL # : 206631 Available: 8Shop NowRegular price $363.83Regular priceUnit price / per$385.00Sale price $363.83Sale -
Vendor: TRANE
Bearing; Complete Thrust Bearing Kit Shims and Key 2.875" Diameter
SCL # : 206476 Available: 2Shop NowRegular price $3,024.00Regular priceUnit price / per$3,200.00Sale price $3,024.00Sale -
Vendor: NTN
Fan Shaft Pillow Block Bearing 2 1/4" Bore
SCL # : 206385 Available: 8Shop NowRegular price $151.20Regular priceUnit price / per$160.00Sale price $151.20Sale -
Vendor: REXNORD
Bearing; Pillow Block, Med. Duty
SCL # : 205956 Available: 2Shop NowRegular price $614.25Regular priceUnit price / per$650.00Sale price $614.25Sale -
Vendor: SEALMASTER
Standard Duty Bearing with Cast Iron Housing 1 15/16" Bore
SCL # : 205909 Available: 7Shop NowRegular price $94.50Regular priceUnit price / per$100.00Sale price $94.50Sale -
Vendor: TRANE
Ctv Flanged Bearing 3 Bore "
SCL # : 205812 Available: 2Shop NowRegular price $378.00Regular priceUnit price / per$400.00Sale price $378.00Sale -
Vendor: POWER DRIVE
1-11/16" Bore Keyed Flange Bushing
SCL # : 205766 Available: 1Shop NowRegular price $17.01Regular priceUnit price / per$18.00Sale price $17.01Sale -
Vendor: TRANE
1-15/16 Bore Fan Hub Bushing "
SCL # : 205746 Available: 2Shop NowRegular price $189.00Regular priceUnit price / per$200.00Sale price $189.00Sale -
Vendor: LAU
Randall Oil Bearing Bore 1"
SCL # : 200210 Available: 2Shop NowRegular price $12.00Regular priceUnit price / per$0.00Sale price $12.00 -
Vendor: BROWNING
B-44 Supergrip Belt
SCL # : 166140 Available: 14Shop NowRegular price $9.00Regular priceUnit price / per$0.00Sale price $9.00 -
Vendor: BROWNING
Gripnotch V-Belt, 1/2" X 36"
SCL # : 95667 Available: 12Shop NowRegular price $4.73Regular priceUnit price / per$5.00Sale price $4.73Sale -
Vendor: JASON INDUSTRIAL
5/8" X 39" V-Belt
SCL # : 85584 Available: 2Shop NowRegular price $7.56Regular priceUnit price / per$8.00Sale price $7.56Sale -
Vendor: LAU
3/4" Flange Bearing
SCL # : 76684 Available: 1Shop NowRegular price $7.56Regular priceUnit price / per$12.00Sale price $7.56Sale -
Vendor: JASON INDUSTRIAL
V Belt 5/8" X 55"
SCL # : 75907 Available: 2Shop NowRegular price $4.73Regular priceUnit price / per$5.00Sale price $4.73Sale -
Vendor: DIAL MANUFACTURING
64"L V-Belt X 3/4"W
SCL # : 72227 Available: 2Shop NowRegular price $1.80Regular priceUnit price / per$3.00Sale price $1.80Sale -
Vendor: LAU
1" Thrust Spacer Kit
SCL # : 41838 Available: 3Shop NowRegular price $2.00Regular priceUnit price / per$3.37Sale price $2.00Sale -
Vendor: MARS
1" Bore Pillow Block Bearing
SCL # : 38051 Available: 6Shop NowRegular price $13.00Regular priceUnit price / per$0.00Sale price $13.00
Frequently Asked Questions
The HVAC blower motor is the component inside a furnace or air handler that drives the fan wheel, circulating conditioned air through the ductwork and into occupied spaces during both heating and cooling cycles. Without a functioning blower motor, a system can heat or cool the air internally but cannot deliver it to the rooms, making the motor essential to comfort even when all other system components are working correctly. Blower motors in residential systems are typically direct-drive units housed inside the air handler cabinet, designed to run continuously or cycle on with the system depending on thermostat settings.
The most common indicators of a failing furnace blower motor are no airflow or noticeably weak airflow from supply vents even when the system is running, which suggests the motor is no longer driving the fan at proper speed. Unusual sounds from the air handler cabinet, such as grinding, squealing, or rattling, can point to worn bearings or loose internal components; overheating and burning odors are more urgent warning signs that warrant immediate shutdown.
Higher-than-expected energy bills and unpredictable starts and stops are also common signs of a motor working harder than it should and approaching its end.
PSC blower motor (Permanent Split Capacitor) units are straightforward, lower-cost, and still common in the field, though new equipment shifted away from them following 2019 DOE energy efficiency regulations. ECM blower motors (Electronically Commutated Motors) are variable-speed units that adjust airflow output in real time based on system demand, consuming significantly less energy, operating more quietly, and delivering more consistent temperatures than single-speed alternatives. ECMs carry a longer service life and a higher upfront cost; they also require more care in installation and programming, and ECM replacement typically calls for professional involvement rather than a straightforward DIY swap.
For a PSC motor, the key specs to match from the original motor's nameplate are horsepower (HP), voltage (typically 115V or 208/230V), RPM (commonly 1075), rotation direction (clockwise or counter-clockwise viewed from the shaft end), frame size (48-frame is standard for residential), and shaft diameter and length. Capacitor specifications, including microfarad rating and voltage, must also match for PSC motors, since a mismatched capacitor prevents proper starting; for ECM motors, blower motor compatibility with the system's control board is the critical additional factor beyond electrical ratings. The most reliable starting point is the motor nameplate on the unit being replaced; Surplus City's team at 765-482-7000 can assist with spec matching if the nameplate is difficult to read or the motor has already been removed.
It’s best to work with a licensed contractor for blower motor replacement. The PSC motor replacement process involves disconnecting power, removing the old motor, transferring the blower wheel, and installing the new unit with matched wiring; professional installers typically complete the job in two to four hours. ECM motor replacement is more complex due to the integrated electronic control module and (in some systems) the need to program the motor to communicate with the furnace control board. Professional installation is generally recommended to avoid control board damage or programming errors. Confirming power is fully disconnected at the breaker before opening the air handler cabinet is the critical first step.
Professional replacement, including parts and labor, typically runs between $300 and $900 for residential systems; PSC motor parts generally range from $100 to $300, while ECM motors can run $300 to $800 or more, with labor adding $150 to $250 on top. Sourcing the motor independently through a discount HVAC blower motor supplier rather than through a service company can reduce the parts cost significantly. This is a common approach for contractors managing job margins and for homeowners handling their own replacement. Whether to replace just the blower motor or evaluate a full system replacement depends on the age and overall condition of the unit; a motor failure in a system over 15 to 20 years old warrants that broader assessment.
All surplus HVAC blower motors at Surplus City Liquidators are brand-new and have never been installed. No reconditioned, pulled, or previously used inventory is sold. Surplus City sources directly from manufacturers in large quantities, which is how it provides below-market pricing without compromising product condition or specifications. Motors arrive in original manufacturer packaging with full nameplate data intact, making it straightforward to verify specs before installation.
Blower motors and motor assemblies ship nationwide. Shipping options and costs are selected at checkout based on the customer's preferred shipping method. Larger or heavier assemblies may require a custom freight quote, in which case the Surplus City team will contact the buyer within 3 to 5 business days with confirmed pricing before any freight charges are applied. Customers can also check online for pickup locations and stock availability.
















