SCL # :78893
Manufacturer Item # :S8910U1000
Alternate Part # :S8910U
Universal Hot Surface Ignition Module, Input Voltage:120 & 24 Vac, 60 Hertz, Hsi 120Vac, 5A Max.
Valve 24Vac, 2A Max, Total 24 Vac Load 0.4 Valve Load. Single Rod (Local Sense) Or Two Rod (Remote Sense) Flame Sensing. Non-100 Persent Shutoff, 100 Percent Shutoff/Lockout, Or 100 Percent Shutoff/Continuous Retry, Natural Or Lp Gas, Shutoff/Lockout Times Of 15 Seconds Or Longer, Prepurge Configurable To 30 Seconds Or No Prepurge, Pilot Burners With Flow Rates Of 1,500 Btuh Or Less, With Or Without Integral Damper Connector. Diagnostic Led Indicates Control Status And Error Codes, Dimensions: 4"H x 5-1/4"W x 1-3/4"D, Weight: 1 lbs
Valve 24Vac, 2A Max, Total 24 Vac Load 0.4 Valve Load. Single Rod (Local Sense) Or Two Rod (Remote Sense) Flame Sensing. Non-100 Persent Shutoff, 100 Percent Shutoff/Lockout, Or 100 Percent Shutoff/Continuous Retry, Natural Or Lp Gas, Shutoff/Lockout Times Of 15 Seconds Or Longer, Prepurge Configurable To 30 Seconds Or No Prepurge, Pilot Burners With Flow Rates Of 1,500 Btuh Or Less, With Or Without Integral Damper Connector. Diagnostic Led Indicates Control Status And Error Codes, Dimensions: 4"H x 5-1/4"W x 1-3/4"D, Weight: 1 lbs
Product Details
Product Details
SCL # :78893
Manufacturer Item # :S8910U1000
Alternate Part # :S8910U
Universal Hot Surface Ignition Module, Input Voltage:120 & 24 Vac, 60 Hertz, Hsi 120Vac, 5A Max.
Valve 24Vac, 2A Max, Total 24 Vac Load 0.4 Valve Load. Single Rod (Local Sense) Or Two Rod (Remote Sense) Flame Sensing. Non-100 Persent Shutoff, 100 Percent Shutoff/Lockout, Or 100 Percent Shutoff/Continuous Retry, Natural Or Lp Gas, Shutoff/Lockout Times Of 15 Seconds Or Longer, Prepurge Configurable To 30 Seconds Or No Prepurge, Pilot Burners With Flow Rates Of 1,500 Btuh Or Less, With Or Without Integral Damper Connector. Diagnostic Led Indicates Control Status And Error Codes, Dimensions: 4"H x 5-1/4"W x 1-3/4"D, Weight: 1 lbs
Valve 24Vac, 2A Max, Total 24 Vac Load 0.4 Valve Load. Single Rod (Local Sense) Or Two Rod (Remote Sense) Flame Sensing. Non-100 Persent Shutoff, 100 Percent Shutoff/Lockout, Or 100 Percent Shutoff/Continuous Retry, Natural Or Lp Gas, Shutoff/Lockout Times Of 15 Seconds Or Longer, Prepurge Configurable To 30 Seconds Or No Prepurge, Pilot Burners With Flow Rates Of 1,500 Btuh Or Less, With Or Without Integral Damper Connector. Diagnostic Led Indicates Control Status And Error Codes, Dimensions: 4"H x 5-1/4"W x 1-3/4"D, Weight: 1 lbs
Specifications
Specifications
Cabinet Size:5.25
Circuit Voltage:115-120
Maximum Hertz:60
Packaging:Manufacture packaging