-
Proveedor: HUBA CONTROLS
Interruptor de presión de puerto doble WC .172 "
Número de serie: 210010 Disponible: 9Comprar ahoraPrecio regular $41.45Precio regularPrecio unitario / por$51.00Precio de venta $41.45Venta -
Proveedor: HONEYWELL
Sensor de presión diferencial baja 5 Vcc
Número de serie: 209922 Disponible: 1Comprar ahoraPrecio regular $16.02Precio regularPrecio unitario / por$18.00Precio de venta $16.02Venta -
Proveedor: ENDURA
Interruptor; Interruptor de presión de aire del horno, abierto - 1,18 WC
Número de serie: 209916 Disponible: 2Comprar ahoraPrecio regular $14.24Precio regularPrecio unitario / por$16.00Precio de venta $14.24Venta -
Proveedor: ALPHA TECHNICS
Sensor de temperatura del aire mezclado
Número de serie: 209883 Disponible: 5Comprar ahoraPrecio regular $81.74Precio regularPrecio unitario / por$93.00Precio de venta $81.74Venta -
Proveedor: RESIDEO
Interruptor de presión de 2 etapas .65 WC 24 V CA 60 Hz"
Número de serie: 209773 Disponible: 4Comprar ahoraPrecio regular $28.12Precio regularPrecio unitario / por$32.00Precio de venta $28.12Venta -
Proveedor: ALPHA TECHNICS
Sensor de temperatura del aire mezclado
Número de serie: 209758 Disponible: 1Comprar ahoraPrecio regular $159.95Precio regularPrecio unitario / por$182.00Precio de venta $159.95Venta -
Proveedor: SAGINOMIYA
Sensor de alivio de presión
Número de serie: 209713 Disponible: 3Comprar ahoraPrecio regular $29.12Precio regularPrecio unitario / por$46.00Precio de venta $29.12Venta -
Proveedor: HOFFMAN
Kit de control de presión de aire ambiente baja; 208-230 V (460 V), 50/60 Hz
Número de serie: 209651 Disponible: 3Comprar ahoraPrecio regular $60.78Precio regularPrecio unitario / por$96.00Precio de venta $60.78Venta -
Proveedor: HONEYWELL
Interruptor; Presión Negativa, 120 V, 3 Fla, 1/10 Hp
Número de serie: 209456 Disponible: 57Comprar ahoraPrecio regular $15.84Precio regularPrecio unitario / por$18.00Precio de venta $15.84Venta -
Proveedor: SINGER/AMANA
Interruptor de presión, 125-250 V CA/50-60
Número de serie: 209450 Disponible: 10Comprar ahoraPrecio regular $18.99Precio regularPrecio unitario / por$30.00Precio de venta $18.99Venta -
Proveedor: SAGINOMIYA
Interruptor de control de presión; abierto 90 PSIG, cerrado 180 PSIG, 90Op/180Cl
Número de serie: 209396 Disponible: 28Comprar ahoraPrecio regular $4.70Precio regularPrecio unitario / por$5.00Precio de venta $4.70Venta -
Proveedor: TRANE
Kit; Restrictor de control de flujo estilo B, para uso con MCW512F
Número de serie: 209339 Disponible: 4Comprar ahoraPrecio regular $17.86Precio regularPrecio unitario / por$19.00Precio de venta $17.86Venta -
Proveedor: TRANE
Conjunto de adaptador/carcasa de control de flujo; para uso con Mcw518F
Número de serie: 209199 Disponible: 37Comprar ahoraPrecio regular $12.22Precio regularPrecio unitario / por$13.00Precio de venta $12.22Venta -
Proveedor: HONEYWELL
Control de presión de aire
Número de serie: 209177 Disponible: 674Comprar ahoraPrecio regular $15.84Precio regularPrecio unitario / por$18.00Precio de venta $15.84Venta -
Proveedor: SAGINOMIYA
Control de baja presión 250 V
Número de serie: 208713 Disponible: 16Comprar ahoraPrecio regular $24.34Precio regularPrecio unitario / por$28.00Precio de venta $24.34Venta -
Proveedor: JOHNSON CONTROLS
Control de corte de alta presión; conector abocardado macho de 1/4"
Número de serie: 208516 Disponible: 21Comprar ahoraPrecio regular $61.60Precio regularPrecio unitario / por$70.00Precio de venta $61.60Venta -
Proveedor: SAGINOMIYA
Control; cables conductores de color gris de alta presión
Número de serie: 208457 Disponible: 52Comprar ahoraPrecio regular $8.23Precio regularPrecio unitario / por$11.00Precio de venta $8.23Venta -
Proveedor: SAGINOMIYA
Control; Baja Presión, 5Op/20Cl
Número de serie: 208425 Disponible: 33Comprar ahoraPrecio regular $7.82Precio regularPrecio unitario / por$10.00Precio de venta $7.82Venta -
Proveedor: CLEVELAND CONTROLS
Interruptor de presión .70WC
Número de serie: 208321 Disponible: 49Comprar ahoraPrecio regular $7.60Precio regularPrecio unitario / por$12.00Precio de venta $7.60Venta -
Proveedor: CLEVELAND CONTROLS
Presostato con rearme manual 120-277/60/1
Número de serie: 208171 Disponible: 31Comprar ahoraPrecio regular $31.28Precio regularPrecio unitario / por$34.00Precio de venta $31.28Venta -
Proveedor: SENSATA
Transductor de presión diferencial 5 V CC 0-50 PSI
Número de serie: 208008 Disponible: 1Comprar ahoraPrecio regular $89.00Precio regularPrecio unitario / por$100.00Precio de venta $89.00Venta -
Proveedor: SENSATA
Corte por baja presión, 240 V CA
Número de serie: 207157 Disponible: 44Comprar ahoraPrecio regular $9.08Precio regularPrecio unitario / por$12.00Precio de venta $9.08Venta -
Proveedor: SAGINOMIYA
Control de baja presión de 30 Op/40 Cl, capilar de 32'
Número de serie: 207002 Disponible: 2Comprar ahoraPrecio regular $89.15Precio regularPrecio unitario / por$106.00Precio de venta $89.15Venta -
Proveedor: TEXAS INSTRUMENTS
Recorte-Presión baja
Número de serie: 206798 Disponible: 60Comprar ahoraPrecio regular $8.44Precio regularPrecio unitario / por$12.00Precio de venta $8.44Venta
Frequently Asked Questions
A pressure control is a safety and operating device that monitors refrigerant pressure at a designated point in the system and opens or closes an electrical circuit in response to preset pressure thresholds. Surplus pressure controls for HVAC and refrigeration applications serve this function in air conditioners, heat pumps, commercial refrigeration systems, and chillers.
The primary function is compressor protection: if system pressure falls below a safe minimum or rises above a safe maximum, the pressure control interrupts power to the compressor before damage occurs. Any application where refrigerant pressure directly affects equipment safety and system performance relies on a functioning pressure control.
A low pressure switch in HVAC monitors the suction side of the refrigerant circuit and shuts off the compressor when pressure drops below a preset cutout point, typically signaling a refrigerant loss, restriction, or evaporator freeze condition. A high pressure switch in HVAC monitors the discharge side and cuts out the compressor when pressure exceeds a safe upper limit, usually caused by a failed condenser fan, blocked coil, refrigerant overcharge, or restricted airflow.
Many residential and commercial systems use both controls together to protect the compressor from both pressure extremes. Some systems use a single dual pressure control that monitors both in one unit.
A head pressure control manages condenser fan operation to maintain adequate discharge pressure in low-ambient-temperature conditions, where cold outdoor air would otherwise allow head pressure to drop below the minimum needed for proper refrigerant flow.
When outdoor temperatures fall, the control cycles or modulates the condenser fan to prevent the system from operating at excessively low head pressure, which can cause liquid slugging, refrigerant floodback, and compressor damage. Head pressure controls are commonly specified for heat pumps, year-round commercial refrigeration, and rooftop units operating in cold climates.
An auto-reset pressure control automatically restores the circuit once system pressure returns to within the acceptable operating range. This is common for low-pressure controls where the triggering condition is less likely to cause immediate equipment damage. A manual-reset pressure control requires a technician to physically reset the switch after it trips, preventing the system from restarting until the underlying fault is diagnosed and corrected.
Selecting the correct reset type is not interchangeable: using an auto-reset high pressure control in an application that requires manual reset can allow a system to repeatedly restart in a fault condition, accelerating compressor damage. The system's wiring diagram and equipment documentation will specify which reset type is required.
All pressure controls in the inventory at Surplus City Liquidators are new surplus HVAC parts that have never been installed. These include manufacturer overstock, not field returns, pull-outs, and rebuilt components.
Surplus City acquires inventory directly from manufacturers offloading excess production that was not sold through standard distribution channels. Buyers receive factory-new discount HVAC pressure controls in original packaging. The savings reflect excess supply, not any reduction in component condition or specification.
The Surplus City Liquidators collection includes brand-name pressure controls from established HVAC and refrigeration manufacturers; specific brands vary based on current manufacturer surplus availability.
Ranco (distributed under the Robertshaw brand) is one of the most widely recognized names in HVAC pressure controls, with a full range of low pressure, high pressure, and dual pressure models. Other common names in this category include Honeywell, ICM Controls, and OEM-branded components from major equipment manufacturers. Inventory turns regularly; checking the collection page directly provides the most current picture of available brands and part numbers.
Start with the original part number stamped on the existing control or listed in the system's wiring diagram. Ordering by OEM part number is the most reliable method for a correct match. When the original part number is unavailable, key specification fields for any HVAC pressure switch replacement are: pressure type (low, high, or dual), cutout and cut-in PSI settings, refrigerant type compatibility, reset type (auto or manual), connection size and fitting type, and switch voltage rating.
Cross-reference guides for common HVAC pressure controls are widely available from manufacturers and wholesale distributors and can help identify compatible replacements when the original part number is no longer legible.
Pressure controls are not universally refrigerant-agnostic. Cutout and cut-in PSI settings are calibrated to the operating pressure ranges of specific refrigerants, and a control sized for R-22 will operate at incorrect setpoints on an R-410A system.
Modern residential systems predominantly use R-410A, which operates at significantly higher pressures than legacy refrigerants such as R-22 and R-404A. Using a pressure control with setpoints matched to the wrong refrigerant can result in nuisance trips, inadequate protection, or both. Always confirm that the replacement control's pressure range and refrigerant designation match the system's specifications before ordering.
Surplus City Liquidators ships orders to customers across the contiguous United States in addition to offering local pickup at its showroom locations. Orders can be placed directly through the online store; shipping options and processing timelines are available at checkout.
Local pickup is available at Surplus City showroom locations in Lebanon, IN; Lafayette, IN; Grand Prairie, TX; and Greenville, SC. Showroom hours are Monday through Friday, 7:30 a.m. to 4:00 p.m.























