Transmisores de voltaje y dispositivos de medición
-
Proveedor: ADVANCED DISTRIBUTOR PRODUCTS
Pistón Florator de 0,84 de diámetro, refrigerante R-22
Número de serie: 217912 Disponible: 1Comprar ahoraPrecio regular $10.00Precio regularPrecio unitario / porPrecio de venta $10.00 -
Proveedor: SPORLAN
Válvula de expansión termostática de 3 toneladas, R-410A
Número de serie: 212655 Disponible: 1Comprar ahoraPrecio regular $70.00Precio regularPrecio unitario / porPrecio de venta $70.00 -
Proveedor: SPORLAN
Válvula de expansión térmica externa ajustable de 2 toneladas con puerto de purga externo abocardado de 1/4" y ecualizador R-22"
Número de serie: 210389 Disponible: 8Comprar ahoraPrecio regular $47.25Precio regularPrecio unitario / por$50.00Precio de venta $47.25Venta -
Proveedor: EMERSON
Válvula de expansión térmica de 1 a 2 toneladas R-22
Número de serie: 209918 Disponible: 8Comprar ahoraPrecio regular $47.25Precio regularPrecio unitario / por$50.00Precio de venta $47.25Venta -
Proveedor: PARKER
Válvula de expansión termostática de 1 a 1 1/2 tonelada
Número de serie: 207469 Disponible: 8Comprar ahoraPrecio regular $44.42Precio regularPrecio unitario / por$47.00Precio de venta $44.42Venta -
Proveedor: EMERSON
Válvula TXV de flujo doble, balanceada, de temperatura media externa ajustable, de 55 toneladas, con puerto y ecualizador externo de 1/4 Sae R-134A
Número de serie: 182003 Disponible: 5Comprar ahoraPrecio regular $47.25Precio regularPrecio unitario / por$100.00Precio de venta $47.25Venta -
Proveedor: ALCO
Válvula de distribución de aire externa de amplio rango no ajustable de 4 toneladas con puerto de purga externo de 1/8 ODF y ecualizador R-22
Número de serie: 181937 Disponible: 1Comprar ahoraPrecio regular $28.35Precio regularPrecio unitario / por$30.00Precio de venta $28.35Venta -
Proveedor: SPORLAN
Kit de válvula reguladora de presión del evaporador
Número de serie: 150071 Disponible: 40Comprar ahoraPrecio regular $5.63Precio regularPrecio unitario / por$7.00Precio de venta $5.63Venta -
Proveedor: SPORLAN
Válvula de expansión térmica de 1/2 tonelada
Número de serie: 168215 Disponible: 12Comprar ahoraPrecio regular $8.00Precio regularPrecio unitario / por$0.00Precio de venta $8.00 -
Proveedor: SPORLAN
Válvula de expansión termostática de 1/4 de tonelada R-507
Número de serie: 150050 Disponible: 5Comprar ahoraPrecio regular $34.02Precio regularPrecio unitario / por$36.00Precio de venta $34.02Venta -
Proveedor: SPORLAN
Válvula de expansión térmica de 1 a 1,5 toneladas
Número de serie: 91786 Disponible: 5Comprar ahoraPrecio regular $14.18Precio regularPrecio unitario / por$15.00Precio de venta $14.18Venta -
Proveedor: Danfoss
Kit de pistón FloWCheck serie 3863, tamaño de pistón 073
Número de serie: 193017 Disponible: 29Comprar ahoraPrecio regular $2.00Precio regularPrecio unitario / por$0.00Precio de venta $2.00 -
Proveedor: Rheem
Kit de válvula de expansión para serpentines interiores RCBA
Número de serie: 183594 Disponible: 30Comprar ahoraPrecio regular $33.96Precio regularPrecio unitario / por$43.00Precio de venta $33.96Venta -
Proveedor: EMERSON
Válvula de expansión térmica de 3 toneladas
Número de serie: 155747 Disponible: 51Comprar ahoraPrecio regular $5.00Precio regularPrecio unitario / por$8.00Precio de venta $5.00Venta -
Proveedor: EMERSON
Válvula de expansión térmica de 4 toneladas R14A/R12/R401A
Número de serie: 210901 Disponible: 2Comprar ahoraPrecio regular $30.00Precio regularPrecio unitario / por$0.00Precio de venta $30.00 -
Proveedor: ALCO
Válvula de expansión térmica R22 de 55 toneladas
Número de serie: 210888 Disponible: 1Comprar ahoraPrecio regular $113.40Precio regularPrecio unitario / por$120.00Precio de venta $113.40Venta -
Proveedor: ALCO
Válvula TXV 7/8 x 1-1/8ODF
Número de serie: 145479 Disponible: 2Comprar ahoraPrecio regular $94.50Precio regularPrecio unitario / por$100.00Precio de venta $94.50Venta -
Proveedor: EMERSON
Válvula de expansión térmica de 20 toneladas R-22
Número de serie: 170406 Disponible: 4Comprar ahoraPrecio regular $100.00Precio regularPrecio unitario / por$0.00Precio de venta $100.00 -
Proveedor: EMERSON
Válvula de expansión de 3 toneladas - R410A
Número de serie: 215552 Disponible: 476Comprar ahoraPrecio regular $35.00Precio regularPrecio unitario / por$0.00Precio de venta $35.00 -
Proveedor: ARMSTRONG
Kit de válvula de expansión termostática de 1,5 a 2,5 toneladas R-410A
Número de serie: 214708 Disponible: 28Comprar ahoraPrecio regular $50.00Precio regularPrecio unitario / por$0.00Precio de venta $50.00 -
Proveedor: TRANE
Válvula de expansión térmica; R-410A
Número de serie: 211923 Disponible: 31Comprar ahoraPrecio regular $49.14Precio regularPrecio unitario / por$52.00Precio de venta $49.14Venta -
Proveedor: SPORLAN
Válvula de expansión térmica de 3 toneladas con filtro; R-410A
Número de serie: 211673 Disponible: 1Comprar ahoraPrecio regular $60.00Precio regularPrecio unitario / por$0.00Precio de venta $60.00 -
Proveedor: EMERSON
Válvula de expansión del termostato
Número de serie: 210807 Disponible: 7Comprar ahoraPrecio regular $72.77Precio regularPrecio unitario / por$77.00Precio de venta $72.77Venta -
Proveedor: TRANE
Válvula de expansión térmica R-410A, 3/8 ODF x 1/2 ODF
Número de serie: 210670 Disponible: 24Comprar ahoraPrecio regular $25.00Precio regularPrecio unitario / por$0.00Precio de venta $25.00
Frequently Asked Questions
A thermostatic expansion valve (TXV) meters liquid refrigerant into the evaporator coil, opening and closing in response to system demand so the coil receives the right amount of refrigerant as conditions change. It works continuously to hold a steady superheat at the evaporator outlet, which keeps the system efficient whether it is running under a light load or working hard on a hot day. As a core metering device in most modern air conditioning, heat pump, and refrigeration systems, the TXV controls one of the most basic functions in the refrigeration cycle: how much refrigerant reaches the coil at any given moment, rather than relying on a fixed flow rate.
Superheat is the difference between the actual temperature of refrigerant vapor and the temperature at which that refrigerant would boil at the same pressure, and it shows a technician how much heat the refrigerant has absorbed beyond the point where it fully turned from liquid to vapor. A TXV opens and closes to hold superheat at a steady target value as conditions in the system shift, which keeps liquid refrigerant from reaching the compressor, since compressors are built to handle vapor rather than liquid. Correct superheat control protects the compressor from that kind of damage and keeps the system running at the efficiency it was designed for.
The clearest symptoms of a bad TXV valve include inconsistent or poor cooling even though the system runs continuously, since a stuck or misadjusted valve can no longer meter refrigerant correctly. Frost or heavy condensation building up on the suction line or evaporator coil is another common sign, often pointing to too much refrigerant reaching the coil at once. During diagnostics, a technician may also find abnormal or fluctuating superheat and pressure readings that swing outside the expected range, which usually confirms the valve itself, rather than another component, is causing the problem.
Matching a replacement TXV valve starts with confirming the system's refrigerant type, since a valve built for R-22 does not work as an R-410A expansion valve, given that the two refrigerants operate at different pressures and require different internal calibration. Beyond refrigerant type, the replacement also needs to match the system's tonnage, connection size, and equalizer type to the valve being replaced. When any of these details are unclear, the original valve's model number or the system's documentation gives the most reliable reference point for finding a correct match before ordering.
Surplus HVAC parts carry that label because of how they were acquired, not because of prior use. These are factory-new components pulled from discontinued production runs, canceled orders, or manufacturer overstock, and none of them have been installed in a working system. That is a meaningful difference from used parts and refurbished parts.
The TXVs in this collection fall into the first category:
new, unused inventory that carries the same manufacturing condition as a unit purchased at full price through a standard distributor, with the lower cost coming from the sourcing model rather than the condition of the part.
A properly functioning TXV can last for the life of the system it is installed in, since it has no moving parts that wear out the way a mechanical component would. When a TXV does fail, the cause is usually contamination in the refrigerant circuit, wax or sludge buildup inside the valve, moisture that entered the system during a prior repair, or a lost charge in the valve's sensing bulb, the small sensor that reads evaporator outlet temperature, rather than ordinary age-related wear. Because failure tends to trace back to a system condition rather than the valve simply wearing out, addressing the underlying cause during replacement helps prevent the new valve from failing the same way.
Thermostatic expansion valve replacement cost depends on refrigerant type, tonnage, connection size, and brand, so there is no single figure that covers every situation. What stays consistent is that buying new overstock inventory typically costs less than buying the same new part through a standard distributor, since the savings reflect how Surplus City acquires its inventory rather than a difference in part quality. For current pricing on a specific valve, the listed pricing on the TXV collection page reflects what is available today, since overstock pricing can shift as inventory turns over.
Surplus City offers an optional 30-day startup warranty on select equipment categories, but whether TXVs fall under that coverage has not been confirmed yet. Until Surplus City confirms one way or the other, buyers should treat warranty status for this category as an open question rather than assumed coverage, and should check directly with Surplus City for current terms on a specific valve before completing a purchase.
Replacing a TXV requires recovering refrigerant from the system, brazing the new valve into the liquid line, and then evacuating and recharging the system, all of which fall under EPA-certified refrigerant handling requirements. This is not a task suited to a DIY repair. A licensed HVAC or refrigeration technician has the equipment and certification needed to recover refrigerant without releasing it into the atmosphere, braze the new valve in correctly, pull a proper vacuum on the system, and recharge it to the right refrigerant weight. Attempting this work without that certification risks refrigerant release, an improperly brazed joint, or a system that ends up undercharged or overcharged after the repair.













